3717-1-08.1(B)(5) Special requirements: heat treatment dispensing freezers
3717-1 Ohio Uniform Food Safety Code
The heat treatment dispensing freezer is to be equipped with an internal lockout device that cannot be reset without complete disassembly of the machine. The internal lockout device is to mechanically shut down the heat treatment dispensing freezer so that the unit is unable to dispense frozen product if any one of the following occurs:
(a)
The heat treatment cycle is not properly completed;
(b)
The heat treatment cycle has not been completed at least one time in the preceding twenty-four hours; or
(c)
The heat treatment dispensing freezer has not been disassembled for cleaning and sanitizing as specified in paragraph (C)(1) of this rule.